EG4 model names look like a puzzle: a 12kPV that outputs 8,000 W, an 18kPV that outputs 12,000 W, a FlexBOSS21 that is sold as "21kW" but runs 12,000 W from a battery. The number in the name is usually the solar input, not the AC output. This guide lines up all six EG4 inverters we stock, shows what each one really delivers, and matches them to homes, arrays and batteries. Every price and spec below was read from the live product listings on November 15, 2026, and all models were in stock.
Two earlier guides go deeper on parts of this topic, so we do not repeat them here: the EG4 6000XP guide covers string sizing, battery pairing and paralleling for the smallest model, and EG4 vs Sol-Ark compares the two brands head to head.
The three EG4 inverter families
Sort the lineup by family first. The family tells you where the inverter can be mounted, whether it is meant for grid export, and how long the warranty runs. If the terms are new, our guide to hybrid vs off-grid vs grid-tie inverters explains them.
| Family | Models | Built for | Enclosure | Warranty | Name tells you |
|---|---|---|---|---|---|
| XP | 6000XP, 12000XP | Off-grid homes, cabins and backup systems; grid or generator used as an input | IP20, indoor only | 5 years | AC output in watts (6,000 W, 12,000 W) |
| kPV | 12kPV, 18kPV | Grid-tied hybrid systems that also run off-grid; AC coupling for existing solar | NEMA 4X, outdoor | 10 years | Solar input in kW (12 kW, 18 kW); output is 8 kW and 12 kW |
| FlexBOSS | FlexBOSS18, FlexBOSS21 | Grid-tied hybrid systems built around the GridBOSS hub | NEMA 4X, outdoor | 10 years | Solar input in kW (18 kW, 21 kW); output is 13 kW and 12 to 16 kW |
All six are 48V, split-phase 120/240V inverters with built-in MPPT solar charging, so none of them needs a separate charge controller or an autotransformer for 240V loads. How split phase works, and why per-leg limits matter, is covered in split-phase inverters explained.
EG4 inverter lineup at a glance
| Model | Continuous output | Surge | Solar input | MPPT / PV voltage | Battery current or power | Grid pass-through | Weight | Price today |
|---|---|---|---|---|---|---|---|---|
| 6000XP | 6,000 W | 12,000 W for 3.5 s | 8,000 W (4,000 W per tracker) | 2 trackers, 100-480 V | 125 A charge / 140 A discharge | 50 A | 52.9 lb | $1,499 |
| 12000XP V2 (in PowerPro systems) | 12,000 W | 18,000 W for 5 s | 24,000 W (12,000 W per tracker) | 2 trackers, MPPT 120-385 V | 250 A | 100 A grid / 90 A generator | 104.7 lb | $8,685 with 2 batteries |
| 12kPV | 8,000 W | 16,000 W for 0.5 s | 12,000 W used (15,000 W array) | 2 trackers, 4 strings, 100-600 V | 167 A | 80 A | 110 lb | $2,999 |
| 18kPV | 12,000 W | 15,500 W for 5 min with solar | 18,000 W | 3 trackers, 100-600 V* | see manual | 200 A grid / 90 A generator | 121 lb* | $4,898 ($4,798 with ECO100) |
| FlexBOSS18 | 13,000 W | 20,000 W for 0.5 s | 18,000 W | 2 trackers, 4 strings, 100-600 V | 10,000 W | 90 A | 115 lb | $3,199.99 |
| FlexBOSS21 | 12,000 W (16,000 W with solar) | 24,000 W for 0.5 s | 21,000 W used (25,000 W array) | 3 trackers, 5 strings, 100-600 V | 12,000 W | 90 A | 88 lb | $4,129.99 |
Specs from the product listings on November 15, 2026. *The standalone 18kPV listing does not state PV voltage or weight; these two figures come from our 18kPV bundle listings.

Continuous output without solar assist vs maximum solar input. Source: Eco Solar Kits product listings.
Three things stand out. The FlexBOSS18 has the highest continuous rating and costs $1,698 less than the 18kPV. The FlexBOSS21 is not a 21 kW inverter: it is a 12 kW inverter that reaches 16 kW only while the array is producing. And the 12000XP takes the largest array of all, 24,000 W, but it is an indoor off-grid unit that we sell inside PowerPro systems, not on its own.
Which size do you need? The load math
Size the inverter from the loads that run at the same moment, then add 25% headroom. Here is a typical gas-heated house on a summer evening:
| Load | Running watts |
|---|---|
| 3-ton central air conditioner | 3,500 W |
| 1 HP well pump | 1,000 W |
| Refrigerator and freezer | 300 W |
| Microwave | 1,200 W |
| Washer | 500 W |
| Lights, TV, router, chargers | 500 W |
| Total at once | 7,000 W |
| With 25% headroom | 8,750 W |
8,750 W is above the 12kPV (8,000 W) and inside the FlexBOSS18, FlexBOSS21, 18kPV and 12000XP. Take the air conditioner out and the list drops to 3,500 W, or 4,375 W with headroom, which a single 6000XP carries. Add an electric range or dryer (about 5,000 W each) and you are in 12 to 13 kW territory or pairing two units.
Check each 120V leg as well. The 12kPV listing gives 4,000 W per line and the 18kPV 6,000 W per line on grid, so a 240V inverter can still trip if most 120V loads sit on one leg. The full method, including motor start-up surge, is in what size inverter do I need.

Price per kW of continuous output (price / rated kW without solar assist), best code applied. Our calculation from prices on November 15, 2026.
Solar input: how many panels each model takes
The number in most EG4 names is the solar input, and it sets the largest array the inverter can use. The table uses the Sungold 440W panel we sell (Voc 39.03 V) and our usual output formula: kW x 4.5 sun hours x 0.77.
| Model | Solar input | 440W panels at that limit | Daily output at 4.5 sun hours | Max panels per string (cold Voc) |
|---|---|---|---|---|
| 6000XP | 8,000 W | 18 (7.92 kW) | 27.4 kWh | 9 at 480 V |
| 12kPV | 12,000 W | 27 (11.88 kW) | 41.2 kWh | 13 at 600 V |
| 18kPV | 18,000 W | 40 (17.6 kW) | 61.0 kWh | 13 at 600 V |
| FlexBOSS18 | 18,000 W | 40 (17.6 kW) | 61.0 kWh | 13 at 600 V |
| FlexBOSS21 | 21,000 W | 47 (20.68 kW) | 71.7 kWh | 13 at 600 V |
| 12000XP V2 | 24,000 W | 54 (23.76 kW) | 82.3 kWh | confirm in manual |
Cold weather raises panel voltage, so we multiply Voc by 1.14 before counting panels: 39.03 V x 1.14 = 44.5 V, and 13 panels reach 578 V on a 600 V input. The FlexBOSS trackers work best between 120 and 440 V, so strings of 8 to 12 panels are the practical range. These string counts are our calculation, not EG4 wiring diagrams; the manual and your installer have the last word. For the method, see solar panels in series vs parallel.

Array size, not inverter watts, decides how much energy you make in a day.
The tracker count matters on complicated roofs. Each tracker follows one group of strings, so east and west faces should land on different trackers. The FlexBOSS21 and 18kPV have three; the others have two.
Battery pairing and battery-only output
An inverter can only deliver what its battery bank can supply when the grid is down and the sun is not out. Battery current at 48V is watts / 51.2 V / 0.92 efficiency. That gives about 127 A at 6,000 W, 170 A at 8,000 W, 212 A at 10,000 W and 255 A at 12,000 W.
| Model | Battery-side limit | One WallMount 314Ah (200 A, 10.2 kW) | One PowerPro 280Ah (140 A) | For full output from batteries |
|---|---|---|---|---|
| 6000XP | 140 A discharge | Covers 6,000 W | Covers 6,000 W at its limit | 1 battery |
| 12kPV | 167 A | Covers 8,000 W | About 6.6 kW | 1 WallMount or 2 PowerPro |
| FlexBOSS18 | 10,000 W | Covers the 10 kW battery limit | About 6.6 kW | 1 WallMount or 2 PowerPro |
| FlexBOSS21 | 12,000 W | 10.2 kW | About 6.6 kW | 2 batteries |
| 18kPV | 255 A at 12,000 W (our calculation) | 10.2 kW | About 6.6 kW | 2 batteries |
| 12000XP V2 | 250 A | 10.2 kW | About 6.6 kW | 2 batteries |
Note the FlexBOSS18 line. Its 13,000 W rating applies with grid or solar present; from batteries alone the listing caps charge and discharge at 10,000 W. That is still more than the 12kPV, and one EG4 WallMount 16 kWh All-Weather battery ($3,749.99) matches it exactly. The 280Ah PowerPro battery ($3,124) is rated 140 A continuous, about 6.6 kW by the same formula, so 12 kW inverters need two. How many kWh you need for your outage plan is a separate question, answered in how many batteries do I need for solar.
The listings name EG4 280Ah and 314Ah batteries and BigBattery ETHOS for closed-loop communication and for the UL 9540 system pairing with the 12kPV and FlexBOSS models. Inspectors often ask for that pairing on grid-tied battery systems.
GridBOSS, pass-through and whole-home backup
Pass-through current decides where the inverter sits in your electrical system. An inverter wired between the meter and the main panel has to carry everything the house draws from the grid.
- 18kPV: 200 A. It can sit ahead of a 200 A main panel and back up the whole house by itself.
- 12000XP: 100 A, FlexBOSS18 and FlexBOSS21: 90 A, 12kPV: 80 A. These feed a critical-loads subpanel, or a whole 100 A service where the numbers allow.
- 6000XP: 50 A. A subpanel for essentials.
The GridBOSS closes that gap for the FlexBOSS models. Per our bundle listing it is a 200 A split-phase microgrid interconnect device for whole-home backup, load management and AC coupling: it sits between the grid, the main panel and the inverter, and an existing grid-tied solar inverter can connect to its GEN port. It ships without breakers. It is optional, and it adds $1,800 to the FlexBOSS21 and WallMount All-Weather sets we sell ($9,349 against $7,549 for one inverter and one battery).
Seven EG4 picks in detail
1. EG4 FlexBOSS18

$3,199.99 (list $3,599) - 13,000 W continuous, 18,000 W solar, no code today
The FlexBOSS18 gives the most continuous power per dollar in the lineup: $246 per kW. It carries 13,000 W with 20,000 W for half a second and 15,000 W for one second for motor starts, takes 18,000 W of solar on two trackers and four strings (26 A each, 100 to 600 V), and passes 90 A from the grid. It is the only model here that lists built-in 4G next to Wi-Fi, which keeps monitoring alive where home internet is unreliable. NEMA 4X, 115 lb, up to 10 units in parallel, UL 1741 and UL 9540, 10-year warranty.
- Highest continuous rating in the lineup
- Outdoor rated, 10-year warranty
- 4G monitoring without home Wi-Fi
- Battery-only output is capped at 10,000 W
- Two trackers, not three
- 90 A pass-through: whole-home backup on 200 A service needs a GridBOSS
2. EG4 6000XP

$1,499 (list $1,699) - 6,000 W, 8,000 W solar, no code today
The entry point to the range and the lowest price per kW after the FlexBOSS18. It delivers 6,000 W of split-phase power with a 12,000 W surge for 3.5 seconds, takes 4,000 W of solar on each of two trackers (100 to 480 V) and charges at up to 125 A. It is an indoor IP20 unit of 52.9 lb with a 5-year warranty, and up to 16 run in parallel, so a cabin system can grow into a house system. Setup details are in our 6000XP guide.
- $1,499 for a 120/240V inverter with solar charging
- Parallels up to 16 units
- Light enough for one person to hang
- Indoor only, 32F to 113F
- Off-grid design, not for export
- 5-year warranty, half that of the hybrids
3. EG4 12kPV

$2,999 (list $3,169) - 8,000 W, 12,000 W solar, no code today
The lowest-priced EG4 that is built for a grid connection. It runs 8,000 W continuous with 16,000 W for half a second and 10,000 W for a minute, uses up to 12,000 W of solar from four strings on two trackers (MPPT 120 to 500 V), moves 167 A to and from the battery and passes 80 A from grid or generator. The listing shows UL 9540 and UL 1741, a NEMA 4X enclosure, under 55 W of standby draw, 110 lb and a 10-year warranty. It accepts lead-acid as well as lithium banks.
- Outdoor rated and grid-tied for $2,999
- 500 V tracking window suits long strings
- One 200 A wall battery covers its full output
- 8,000 W is tight for homes with central air plus a well pump
- 4,000 W per 120V leg
- $375 per kW, the second highest here
4. EG4 FlexBOSS21

$4,129.99 (list $4,199.99) - 12,000 W (16,000 W with solar), 21,000 W solar, no code today
Pick the FlexBOSS21 for a large or multi-direction array. Three trackers and five strings use 21,000 W of solar (25,000 W recommended array), about 47 of our 440 W panels. Output is 12,000 W from battery or grid and 16,000 W while solar is assisting, with 24,000 W for half a second. Battery charge and discharge reach 12,000 W, pass-through is 90 A, and up to 16 units parallel. At 88 lb it is lighter than the FlexBOSS18. NEMA 4X, UL 1741 and UL 9540, 10-year warranty.
- 21 kW of solar on three trackers
- Full 12 kW from batteries
- Parallels to 16 units
- 16 kW is only available while the sun is out
- $930 more than the FlexBOSS18 for 1,000 W less continuous output
- Needs two batteries for full battery output
5. EG4 18kPV

$4,898 (list $5,482) - 12,000 W, 18,000 W solar, $4,798 with code ECO100
The 18kPV is the established 12 kW hybrid and the only EG4 here with a 200 A grid bypass, so it can sit ahead of a 200 A main panel without extra hardware. It holds 12,000 W, with 13,500 W for 10 minutes without solar and 15,500 W for 5 minutes with solar, takes 18,000 W on three trackers, has built-in breakers and a 90 A generator input, and parallels to 10 units. IP65 / NEMA 4X. Code ECO100 takes $100 off orders of $1,500 or more. It is also the inverter inside our BigBattery ETHOS systems in the EG4 solar kits collection.
- 200 A pass-through for whole-home backup
- Three trackers and built-in breakers
- Long track record and many matched battery bundles
- Highest price per kW here, $400 with the code
- 68 dB at 3 ft per the listing, louder than the FlexBOSS models (under 50 dB)
- Listing has no PV voltage, weight or warranty line
6. EG4 PowerPro 12kW 28.7 kWh (12000XP V2)

$8,685 (list $9,565) - 12,000 W, 28.6 kWh, no code today
This is how we sell the 12000XP V2: one inverter with two EG4 280Ah All-Weather batteries, already matched for closed-loop communication. The inverter gives 12,000 W at 240V with 18,000 W for 5 seconds, switches in under 10 ms, takes 24,000 W of solar (12,000 W per tracker, MPPT 120 to 385 V) and moves 250 A on the battery side, with 100 A grid and 90 A generator bypass. The batteries are IP65, self-heating, 14.3 kWh and 140 A each. The inverter is IP20 and must stay indoors; its warranty is 5 years, the batteries 10.
- Largest solar input of any EG4 here
- Two batteries cover the full 12 kW
- Batteries can live outside and heat themselves
- Inverter is indoor only
- Sold as an off-grid system
- Maximum PV voltage is not on the listing - confirm before designing strings
7. EG4 FlexBOSS21 + WallMount 16 kWh All-Weather

$7,549 (list $8,149) for 1 inverter + 1 battery - $11,744 with 2 batteries, $9,349 with GridBOSS, no code today
A complete outdoor system: the NEMA 4X FlexBOSS21 beside an IP67 battery with internal heaters, so nothing needs garage space. The battery stores 16 kWh (12.86 kWh at 80% depth of discharge), delivers 200 A or 10.2 kW continuously and is covered for 10 years or 10,000 cycles. Each set includes a conduit box and the battery cables. Bought separately the inverter and battery cost $7,879.98, so the set saves $330.98. The listing shows the DC system as UL 9540 with the FlexBOSS21.
- Whole system mounts on an exterior wall
- Set costs less than the parts
- GridBOSS sets available for whole-home backup
- One battery limits battery-only output to 10.2 kW
- 309 lb battery needs a solid wall and two installers
- GridBOSS ships without breakers
Which EG4 inverter fits which home
| Your situation | EG4 model | Why |
|---|---|---|
| Off-grid cabin or essentials subpanel, loads under 4,500 W | 6000XP | Lowest cost; add a second unit later |
| Grid-connected home, no central air, array up to 12 kW | 12kPV | Outdoor hybrid at $2,999 |
| Typical home with central air and a well pump | FlexBOSS18 | 13,000 W continuous at the best price per kW |
| Large or east-west array, 18 to 21 kW of panels | FlexBOSS21 | Three trackers, 21,000 W solar |
| Whole-home backup on 200 A service without a GridBOSS | 18kPV | 200 A grid bypass |
| Off-grid full-size home with indoor equipment space | PowerPro 12kW system (12000XP V2) | 12 kW, 24,000 W solar, matched batteries |
| Adding batteries to existing grid-tied solar | FlexBOSS21 set with GridBOSS | AC coupling through the GridBOSS GEN port |
Browse all of them in the EG4 inverters collection, compare with other brands in hybrid inverters, or see the 10 kW class from other makers in our best 10,000-watt inverters guide. Matching batteries are in EG4 batteries.
What buyers ask before choosing an EG4 inverter
These questions come from what people type into Google before landing on our EG4 pages (Search Console, last 90 days) and from the questions Google shows for EG4 inverters.
Can I buy the EG4 12000XP on its own?
Searches for the 12000XP price are common. In our store the 12000XP V2 is sold inside PowerPro systems, such as the 12 kW system with 28.7 kWh at $8,685. If you already own batteries and want the inverter alone, call us and we will check availability with the supplier.
Is there an EG4 15K or a 24V EG4 inverter?
Not in the lineup we stock. Every EG4 inverter here is 48V, and output steps from 6 kW to 8, 12 and 13 kW. For a single 15 kW unit, look at the Sol-Ark 15K in our EG4 vs Sol-Ark comparison, or run two EG4 units in parallel. For 12V and 24V systems, see 12V vs 24V vs 48V solar systems.
FlexBOSS21 or 18kPV?
Both give 12,000 W from batteries. The FlexBOSS21 costs $768 less, takes 3,000 W more solar, reaches 16,000 W while the array is producing and weighs 88 lb. The 18kPV has the 200 A bypass and built-in breakers, so it suits a whole-home install without a GridBOSS. With a GridBOSS in the plan, the FlexBOSS21 is the better buy.
Which EG4 inverter and battery for an off-grid cabin?
Most cabins fit a 6000XP. The 6000XP with a WallMount 16 kWh All-Weather battery is $5,414.97 and suits unheated spaces because the battery heats itself; the 6000XP with a NEXUS 14.3 kWh battery starts at $4,544 for indoor installs. Cold-weather charging rules are in our winter power outage guide.
FAQ
What is the difference between EG4 XP, kPV and FlexBOSS inverters?
XP models (6000XP and 12000XP) are indoor IP20 off-grid inverters with a 5-year warranty and the lowest prices. kPV models (12kPV and 18kPV) are outdoor-rated grid-tied hybrids with a 10-year warranty that can also run off-grid. FlexBOSS models (FlexBOSS18 and FlexBOSS21) are the newer outdoor hybrids built to work with the EG4 GridBOSS hub, with more solar input per dollar.
Which EG4 inverter can sell power back to the grid?
The grid-tied hybrids: the 12kPV, 18kPV, FlexBOSS18 and FlexBOSS21. They carry UL 1741 listings and work grid-tied or off-grid. The 6000XP and 12000XP are sold as off-grid inverters: they can use grid or generator power to run loads and charge batteries, but they are not the models to pick for export. Selling power always needs utility approval first.
What is the biggest EG4 inverter?
Of the models we stock, the FlexBOSS21 has the highest output: 12,000 W continuous without solar and 16,000 W when solar is assisting, with 21,000 W of solar input on three trackers. The FlexBOSS18 has the highest continuous rating without help from solar at 13,000 W. For more power, units run in parallel: up to 16 FlexBOSS21 or 10 FlexBOSS18, 12kPV or 18kPV.
Do EG4 inverters work with other battery brands?
Yes. They are 48V inverters and the 12kPV listing names both lead-acid and lithium banks. Closed-loop communication, where the battery reports its state to the inverter, is listed for EG4 280Ah and 314Ah batteries and BigBattery ETHOS, and for the 6000XP also BigBattery NEXUS and HUSKY 2. Other 48V batteries can run on voltage settings; check the UL 9540 pairing if your permit needs one.
Can EG4 inverters be installed outdoors?
The 12kPV, 18kPV, FlexBOSS18 and FlexBOSS21 can: they are NEMA 4X rated for direct outdoor mounting and operate from -13F to 140F. The 6000XP and 12000XP are IP20 indoor units that need a garage, utility room or power shed and are rated for full load between 32F and 113F.
What is the warranty on EG4 inverters?
Per the product listings, the 12kPV, FlexBOSS18 and FlexBOSS21 carry a 10-year manufacturer warranty, as does the 18kPV in the bundles we sell. The 6000XP and 12000XP carry 5 years. EG4 WallMount 314Ah batteries are covered for 10 years or 10,000 cycles and the 280Ah All-Weather battery for 10 years.