What Size Solar System Do I Need? kW & Panel Count Chart (2026)

Modern home with a rooftop solar array, wall-mounted hybrid inverter and lithium batteries

By Serhii Dovzhenko, Solar & Energy Storage Specialist · Updated October 28, 2026 · Prices checked October 28, 2026 · Data verification: Adsec.ca

Quick answerDivide your yearly kWh by (peak sun hours x 365 x 0.75). The average US home uses about 865 kWh a month, so it needs roughly 7-10 kW of panels - 16-23 panels of 450 W. Our top pick for that home is the Sungold SGS12K-PM1-450 ($10,275): 9 kW of panels, 12 kW inverter, 16 kWh battery.

The size of a solar system is the total wattage of its panels (the array), in kilowatts (kW), and you can work it out from one number on your electric bill. Get that right and the panel count, roof space, inverter and battery follow.

This guide gives you the formula, a kW chart by monthly electricity use, a panel-count chart, the roof space each size needs, and how off-grid sizing differs from grid-tied. At the end are seven complete kits from 1.2 kW to 14.4 kW that are in stock and active on October 28, 2026, with store prices before any promo code. Looking for a portable power station instead of a roof system? Our solar generator sizing guide covers watts, Wh and surge.

1. The 3-step solar sizing formula

System size (kW) = yearly kWh / (peak sun hours x 365 x 0.75)

  1. Find your yearly use. Add up the last 12 months of kWh on your utility bills (most utilities show a 12-month graph). No history? Multiply one month by 12, but pick an average month, not a heating or cooling peak. The US average was 865 kWh a month in 2024 according to the EIA - about 10,400 kWh a year.
  2. Find your peak sun hours. A peak sun hour is one hour of full-strength sunlight (1,000 W per square meter). Most of the US gets 3.5-6 a day averaged over the year: roughly 3.5-4 in the Pacific Northwest and the Northeast, 4-4.5 in the Midwest and mid-Atlantic, 4.5-5 in the Southeast and Texas, and 5.5-6.5 in the desert Southwest. For your exact address, NREL's free PVWatts calculator gives a site-specific figure.
  3. Apply a real-world factor. Panels rarely deliver their nameplate rating: heat, wiring, inverter losses, dust and imperfect tilt typically cost 20-25%. We use 0.75, which is cautious; a well-oriented, unshaded south-facing roof often does slightly better.

Worked example: a home using 900 kWh a month (10,800 kWh a year) in Ohio at about 4.2 peak sun hours needs 10,800 / (4.2 x 365 x 0.75) = 9.4 kW. The same home in Arizona at 6 sun hours needs 10,800 / (6 x 365 x 0.75) = 6.6 kW. Location changes the answer by 40% or more, which is why a single "average system size" is only a starting point.

Installers call the same idea a production ratio (yearly kWh per watt of panels); in the US it usually falls between 1.1 and 1.6.

2. Solar system size chart by monthly electricity use

Chart of solar system size in kW needed for 500 to 2,000 kWh of monthly electricity use at 4 and 5.5 peak sun hours
Monthly use Yearly use Size at 4 sun hours Size at 5.5 sun hours 450 W panels (4 / 5.5 h) Typical home
500 kWh 6,000 kWh 5.5 kW 4.0 kW 13 / 9 Small home or condo, gas heat
750 kWh 9,000 kWh 8.2 kW 6.0 kW 19 / 14 Efficient 3-bedroom home
900 kWh 10,800 kWh 9.9 kW 7.2 kW 22 / 16 Average US home
1,250 kWh 15,000 kWh 13.7 kW 10.0 kW 31 / 23 Large home with central AC
1,500 kWh 18,000 kWh 16.4 kW 12.0 kW 37 / 27 All-electric home or one EV
2,000 kWh 24,000 kWh 21.9 kW 15.9 kW 49 / 36 All-electric home, heat pump, two EVs, pool

The chart sizes for 100% of yearly use. Under net metering that is usually the target. Where your utility pays little for exported power, a system covering 60-80% of use, plus a battery to store midday surplus, often pays back faster than a bigger array.

Planning to add load?

Size for the next five years, not the last twelve months. Common additions and their rough yearly use:

  • Electric vehicle: about 3,000-4,000 kWh a year for 12,000 miles (roughly 0.25-0.33 kWh per mile) - add 2.5-3.5 kW of panels at 4 sun hours.
  • Heat pump replacing gas heat: 3,000-6,000 kWh a year depending on climate and house size.
  • Heat-pump water heater: about 1,000-1,500 kWh a year (a standard electric tank uses 3,000-4,000).

Buy an inverter with spare solar input now rather than replace it later - every kit below accepts more panels than it ships with.

3. How many solar panels do I need?

Panels = system size in watts / panel wattage, rounded up. A 9 kW system is 9,000 / 450 = 20 panels of 450 W, or 23 panels of 400 W.

Chart of how many 400W, 450W and 590W solar panels make a 3, 5, 8, 10, 12 and 15 kW system
System size 400 W panels 450 W panels 590 W panels Roof or ground area* Output per day (4 / 5.5 sun h) Shop this size
1 kW 3 3 2 ~55 sq ft 3 / 4.1 kWh 1 kW systems
3 kW 8 7 6 ~160 sq ft 9 / 12.4 kWh Cabin kits
5 kW 13 12 9 ~270 sq ft 15 / 20.6 kWh 5 kW systems
8 kW 20 18 14 ~420 sq ft 24 / 33 kWh 8 kW systems
10 kW 25 23 17 ~530 sq ft 30 / 41 kWh 10 kW systems
12 kW 30 27 21 ~630 sq ft 36 / 50 kWh 12 kW systems
15 kW 38 34 26 ~790 sq ft 45 / 62 kWh 15 kW systems

*Panel area only, based on a 450 W panel of about 23 sq ft (75 x 45 in). Allow extra for fire-code setbacks from ridges and edges, vents and skylights - usable roof is often only 60-70% of the total. Daily output uses the 0.75 factor.

Higher-wattage panels mean fewer panels and fewer mounting points, but they are larger and heavier (a 590 W bifacial panel is close to 90 in long), so check your rafter layout and whether one person can handle them on a roof.

4. "8 kW kit" does not always mean 8 kW of panels

This is the most common mix-up we see. Solar kits are often named after the inverter - its maximum continuous output - not the array. An "8,000 W kit" can ship with 3.3 kW of panels; a "10 kW kit" with 5.4 kW. Both numbers matter, but they answer different questions:

  • Array size (panel kW) decides how many kWh you produce - this is the number from the formula above.
  • Inverter size (kW output) decides how many appliances run at once: well pump, AC compressor, range and dryer together. For off-grid and backup, size it to your largest simultaneous load plus motor surge.
  • Battery size (kWh) decides how long you run after sunset or during an outage.

The table below lists in-stock kits by their real array size. "Est. kWh per month" uses 4.5 sun hours and the 0.75 factor.

Kit Price today Panels (array) Est. kWh / month Inverter Battery Type
Sungold SGM-5K5E $3,145 6 x 200 W = 1.2 kW ~120 5 kW, 120V 5.12 kWh Off-grid
Sungold SGK-5PRO $4,958 6 x 450 W = 2.7 kW ~280 5 kW, 120V 10.24 kWh Off-grid
Sungold SGK-8MAX $6,979 12 x 450 W = 5.4 kW ~550 8 kW, 120/240V 10.24 kWh Off-grid
Sungold SGH-7.6N3E (with panels) $9,121 12 x 500 W = 6.0 kW ~615 7.6 kW, 120/240V 15.36 kWh Hybrid, grid-tie capable
Sungold SGS12K-PM1-450 $10,275 20 x 450 W = 9.0 kW ~925 12 kW, 120/240V, 200A pass-through 16.07 kWh Hybrid, UL 9540 system
Sungold SGH-11N3E (with panels) $16,757 28 x 450 W = 12.6 kW ~1,290 10 kW continuous, 120/240V 30.72 kWh Hybrid, grid-tie capable
Sungold SGH-7.6DN6E (with panels) $18,669 32 x 415 W = 13.3 kW ~1,360 2 x 7.6 kW = 15.2 kW 30.72 kWh Hybrid, grid-tie capable
Sungold SGR-20K32P $15,975 32 x 450 W = 14.4 kW ~1,475 2 x 10 kW = 20 kW 32.14 kWh Off-grid

Specs are from the manufacturer data on each product page. The SGH hybrid kits are also sold without panels if you already have an array or want to source panels locally.

5. Grid-tied vs off-grid sizing

Grid-tied (with or without battery): size the array on your yearly kWh, because the grid absorbs summer surplus and covers winter shortfall under net metering. Check your utility's rules first - some cap system size at 100-120% of past use, and the inverter must be UL 1741 listed for interconnection. A battery is optional and sized for backup or time-of-use savings; our whole-home battery backup cost guide covers that math.

Off-grid: there is no grid to bank surplus, so size for your worst month, usually December. In much of the northern US, December delivers 2-3 peak sun hours against a yearly average of 4. A cabin using 10 kWh a day in winter needs 10 / (2.5 x 0.75) = about 5.3 kW of panels, versus 3.3 kW for the yearly average. Off-grid batteries are sized for 1-3 days without sun (daily kWh x days / 0.9 usable), and a generator usually covers long cloudy spells. See our best off-grid solar kits guide for complete systems by home size.

Safety and permits: roof-mounted and grid-connected systems need a permit and, in most areas, utility approval before you switch on. Have a licensed electrician make the final connections to your main panel, install rapid-shutdown equipment where code requires it, and never connect an inverter or generator to house wiring without a proper interconnection or transfer switch - backfeeding endangers utility line crews.

6. Our picks by home size

Best for the average home

Sungold SGS12K-PM1-450 - 9 kW panels, 12 kW inverter, 16.07 kWh - $10,275

At 900 kWh a month, most of the US needs 7-10 kW of panels, and this kit lands in the middle with twenty 450 W bifacial N-type panels (9 kW, about 925 kWh a month at 4.5 sun hours). The SGS-12K18MAX hybrid inverter accepts 18 kW of solar, so you can double the array later for an EV or heat pump without changing the inverter. It outputs 12 kW at 120/240V, has a 200A pass-through to feed a full main panel, and exports under UL 1741 SB / IEEE 1547. The 16.07 kWh PowerMax 314 battery is IP65 and outdoor-rated, and the inverter and battery are certified together as a UL 9540 energy storage system, which simplifies permitting.

ProsRight-sized array for an average home, 18 kW PV input for growth, UL 9540 pair, outdoor battery, about $1,140 per kW of panels with battery included
ConsRacking not included; one battery covers an evening, not a multi-day outage (2- and 3-battery versions exist)
See the SGS12K-PM1-450
Best for efficient or sunny homes

Sungold SGH-7.6N3E - 6 kW panels, 7.6 kW inverter, 15.36 kWh - $9,121

For a home using 500-700 kWh a month, or an average home in the Southwest, 6 kW covers most of the bill. Twelve 500 W panels feed a 7.6 kW split-phase hybrid inverter (10 kW peak) with three MPPTs and 12 kW of solar input. Storage is three 5.12 kWh server-rack LiFePO4 batteries (15.36 kWh, 7,000+ cycles). The inverter is UL 1741 / CEC listed for grid-tie and carries a 10-year warranty. Without panels the kit is $6,319.99.

ProsLarge battery for the array size, 12 kW PV input, 10-year inverter warranty, panels optional
Cons7.6 kW output is tight for central AC plus a well pump at once; indoor battery rack
See the SGH-7.6N3E
Best for large homes

Sungold SGH-11N3E - 12.6 kW panels, 10 kW inverter, 30.72 kWh - $16,757

Homes using 1,250-1,500 kWh a month in the north, or all-electric homes in the south, need 12-14 kW. This kit pairs twenty-eight 450 W panels (12.6 kW, about 1,290 kWh a month) with a split-phase hybrid inverter rated 10 kW continuous and 11.4 kW peak per its spec table, 15 kW of PV input and six 5.12 kWh batteries in an enclosed cabinet (30.72 kWh) - enough for a full evening and night of normal use. The inverter is IP65, UL 1741 SB and has a 10-year warranty; up to nine can be paralleled. Need more output? The two-inverter SGH-7.6DN6E in the table above gives 15.2 kW.

Pros30 kWh of storage, 15 kW PV input, outdoor-rated inverter, about $1,330 per kW of panels with battery
Cons10 kW continuous (the "11.4 kW" in the title is peak); 28 panels need about 650 sq ft
See the SGH-11N3E
Best value per kW (off-grid)

Sungold SGR-20K32P - 14.4 kW panels, 20 kW inverters, 32.14 kWh - $15,975

For a full-size off-grid home - central air, a well pump, an electric range, a shop - this is the largest array in our in-stock kits and the lowest cost per kW of panels, about $1,110 including batteries. Thirty-two 450 W bifacial panels produce about 1,475 kWh a month at 4.5 sun hours, still roughly 1,000 kWh in a 3-sun-hour winter month. Two 10 kW SPH10048P inverters run in parallel for 20 kW at 120/240V with 22 kW of combined PV input, and two outdoor PowerMax 314 batteries store 32.14 kWh. One limit to know: two PowerMax batteries at 150 A each deliver about 14.5 kW from battery alone, so the full 20 kW is available when the sun is up or with more batteries.

ProsLowest price per kW here, outdoor IP65 batteries, Z-brackets included, expandable to 48 kW
ConsOff-grid inverters - no grid export; about 750 sq ft of panels; battery current caps output near 14.5 kW at night
See the SGR-20K32P
Best mid-size off-grid

Sungold SGK-8MAX - 5.4 kW panels, 8 kW inverter, 10.24 kWh - $6,979

For an off-grid home or year-round cabin using 15-18 kWh a day in summer, the SGK-8MAX supplies 5.4 kW of panels (twelve 450 W) and an 8 kW split-phase inverter with 16 kW peak that handles motors up to 5 HP. Its two MPPTs accept 11 kW of solar, so the array can grow to cover winter. The four 12V 200Ah LiFePO4 batteries (10.24 kWh) have Bluetooth monitoring and self-heat below 33.8°F. Z-brackets are included.

Pros120/240V for a well pump or dryer, 11 kW PV input, cold-weather batteries, about $1,290 per kW of panels
ConsIndoor-only inverter (IP20); 10 kWh is about one night for a full house
See the SGK-8MAX
Best for cabins

Sungold SGK-5PRO - 2.7 kW panels, 5 kW inverter, 10.24 kWh - $4,958

A weekend or seasonal cabin typically uses 4-8 kWh a day - lights, a fridge, a pump, electronics and tools. Six 450 W panels (2.7 kW, about 9 kWh a day at 4.5 sun hours) and 10.24 kWh of self-heating LiFePO4 handle that with a day of reserve. The 5 kW, 120V inverter (10,000 VA peak) has built-in Wi-Fi and accepts up to 5.5 kW of solar, so you can double the array later.

ProsBattery sized generously for the array, Wi-Fi monitoring, room to add panels, Z-brackets included
Cons120V only - no 240V well pump; not enough for a full-time family home
See the SGK-5PRO
Best starter system

Sungold SGM-5K5E - 1.2 kW panels, 5 kW inverter, 5.12 kWh - $3,145

For a shed, workshop, tiny home or a first step into solar, the SGM-5K5E is the lowest-cost complete 48V system we carry. Six 200 W panels (about 3.6 kWh a day at 4 sun hours) charge one 5.12 kWh server-rack battery, and the 5 kW inverter leaves plenty of output for tools. The real advantage is the upgrade path: the inverter accepts 5.5 kW of solar, so you can add panels and batteries over time instead of replacing anything.

ProsLowest entry price, 5 kW output, 5.5 kW solar headroom, 7,000-cycle battery
Cons1.2 kW array is small for daily household use; 50 A standard battery current limits sustained output to about 2.5 kW until you add a second battery
See the SGM-5K5E

7. Which size for which home?

Your home Monthly use Array size Pick
Shed, workshop, tiny home Under 150 kWh 1-1.5 kW SGM-5K5E
Weekend or seasonal cabin 150-300 kWh 2.5-3.5 kW SGK-5PRO
Off-grid home, modest use 400-600 kWh 5-7 kW SGK-8MAX
Efficient grid-tied home or sunny climate 500-700 kWh 5-7 kW SGH-7.6N3E
Average grid-tied home 800-1,000 kWh 7-10 kW SGS12K-PM1-450
Large or all-electric grid-tied home 1,200-1,500 kWh 11-14 kW SGH-11N3E
Large off-grid home 1,000-1,400 kWh 13-16 kW SGR-20K32P

Browse every size: 5 kW, 8 kW, 10 kW, 12 kW, 15 kW and 20 kW solar power systems, or all solar power kits.

8. What our customers ask

Sizing questions reach us by phone, text and email in a few repeating patterns (shared here without any personal details):

  • "Is the 10 kW kit 10 kW of panels?" Buyers often search our store for a "10,000 W" kit and are surprised that the number is the inverter. We walk through array size, inverter size and battery separately, as in section 4.
  • "I need about 20 kWh of storage - what fits my inverter?" Battery requests usually come with an existing inverter. The first question is voltage: most of what we stock is 48V, while some brands use high-voltage stacks, and they are not interchangeable.
  • "How big do I need?" We send the Solar Kit Calculator first, then check the result against 12 months of bills and any EV or heat pump the customer plans to add.
  • "Will I need a trailer?" Yes for most home-size kits: a 450 W panel weighs about 54 lb and a 20-panel kit ships on a pallet, so plan for freight delivery or a trailer pickup.

9. Cost, incentives and codes

The kits above run about $1,100-$1,800 per kW of panels with batteries included, before racking, permits and installation. For grid-tied systems, note that the 30% federal residential clean energy credit (Section 25D) ended for expenditures after December 31, 2025, so payback now depends on your utility rate, net-metering rules and any state or utility rebates (this is not tax advice). Prices in this guide are store prices checked October 28, 2026. One code per order: SAVE250 ($250 off $4,000+) and SAVE500 ($500 off $8,000+) apply to kits at these price levels, and ECO100 gives $100 off $1,500+. Black Friday pricing is tracked in our Black Friday solar deals hub.

10. FAQ

What size solar system do I need for my house?

Divide your yearly electricity use in kWh by (peak sun hours x 365 x 0.75). A home using the US average of about 900 kWh a month needs roughly 10 kW of panels at 4 peak sun hours (Northeast, Midwest, Pacific Northwest) and about 7 kW at 5.5 sun hours (Southwest, Florida). Use 12 months of bills for the most accurate result.

How many solar panels do I need to power a house?

Divide the system size in watts by the panel wattage. The average US home needs 7-10 kW, which is 16-23 panels of 450 W or 18-25 panels of 400 W. All-electric homes and homes with an EV often need 25-35 panels.

How much electricity does a 10 kW solar system produce?

About 30 kWh a day at 4 peak sun hours and 41 kWh a day at 5.5 sun hours after typical losses - roughly 900-1,250 kWh a month, or 11,000-15,000 kWh a year. Shading, roof direction and tilt change the result, so check your address in NREL's PVWatts calculator.

How many panels are in an 8 kW solar system?

Twenty 400 W panels, eighteen 450 W panels or fourteen 590 W panels. An 8 kW array produces about 24 kWh a day at 4 sun hours and needs about 420 sq ft of panel area plus setbacks. Note that some "8 kW kits" are named for an 8 kW inverter and include fewer panels.

Is a 5 kW solar system enough to run a house?

A 5 kW array produces about 450-630 kWh a month depending on sunshine, enough for a small or efficient home but about half to two-thirds of an average home's 865-900 kWh. It is a good size for a cabin, an off-grid home with propane appliances, or a grid-tied home in a sunny state with low use.

Should I size an off-grid system differently?

Yes. Off-grid systems cannot bank summer surplus on the grid, so size the array for your lowest-sun month (often December, at 2-3 peak sun hours in the north), and size the battery for 1-3 days of use without sun. Expect an off-grid array 30-60% larger than a grid-tied one for the same home, plus a generator for long cloudy spells.

Does the inverter size have to match the solar array?

No. The array sets how much energy you produce; the inverter sets how much power you can use at once. Grid-tied arrays are often 10-30% larger than the inverter's AC rating, and hybrid inverters list a maximum solar input - for example 18 kW on a 12 kW inverter - which tells you how far the array can grow.

Still unsure? Send us 12 months of usage and your ZIP code and we will size the array, inverter and battery for you - or start with our full off-grid solar power systems and hybrid solar inverters.